Glossary

Glossary

Plain meanings of the words used in BIM, modular and data center construction, in one sentence each.

Updated 19 November 2026

Clash

Two elements in a building model that take up the same space, or sit closer than they are allowed to. Found by clash detection in Revit, Navisworks or Autodesk Construction Cloud.

More →

Clash resolution

Deciding which element moves, by how much and who changes it, then checking the next model is clear. The step after detection, and where coordination time goes.

More →

BIM

Building information modeling: a 3D model of a building where every element carries data, not just geometry. Revit is the most common BIM tool for design.

More →

LOD

Level of development: how complete and reliable a model element is, from a rough placeholder to what was actually installed. Contracts say which LOD each stage must reach.

More →

IFC

Industry Foundation Classes: an open file format for building models, so different tools can share them. Solibri and many checkers work on IFC.

More →

IDS

Information Delivery Specification: a buildingSMART format for writing down, in a machine-readable way, which information a model must contain. A model can then be checked against it automatically.

More →

QA/QC (BIM)

Quality assurance and quality control for models: checking a model against standards and the project spec before it is issued.

More →

Model checking

Testing a building model against rules (naming, data, sizes, materials, the spec) to find errors before drawings go out.

More →

As-built

A record of what was actually built, as opposed to what was designed. Checking the as-built against the model catches what changed on site.

More →

Scan to BIM

Turning a laser scan or photo survey of a building into a building model. Used for renovations and as-built records.

More →

Reality capture

Measuring what is on site with laser scanners, phone photos or video, to compare it with the model.

More →

DfMA

Design for manufacture and assembly: designing a building so its parts can be made in a factory and put together quickly on site.

More →

Modular construction

Building in factory-made modules or skids that are shipped and set in place on site.

More →

Fixed-position layout

A factory floor where the product stays put and people, tools and materials come to it, as in building large modules.

More →

Commissioning

The stepped testing that proves a building's systems work, from factory tests to all systems running together.

More →

IST

Integrated systems testing: the final commissioning level, where every system runs together and failures are staged on purpose.

More →

Hyperscale

A very large data center campus, often over 100 MW.

More →

Hyperscaler

A large cloud service provider that runs hyperscale data centers. IBM notes the word is also used for the data centers themselves.

More →

Colocation

A data center whose owner rents space, power and cooling to tenants who bring and keep their own servers. Also called colo.

More →

Neocloud

A cloud company built for GPU compute and AI work, renting out GPU capacity.

More →

Liquid cooling

Cooling racks with liquid brought to them, instead of only with air. More pipework to size, coordinate and test.

More →

Cell hall

In a data center, the hall where the racks of computing equipment stand: the white space.

More →

Sources for hyperscaler, colocation and neocloud: IBM, What is a hyperscale data center?; Equinix, What is colocation?; Micron, What is a neocloud?.

All guides